If you’re deep in the world of aptamer selection, you know how much hinges on every step: the right surfaces, precise washing, and conditions that keep target molecules—and their potential binding partners—intact. For years, I’ve heard questions from researchers in labs across the globe, and one that comes up again and again is whether Funke Plates can actually work for this work. As a supplier who’s spent years testing these plates alongside lab teams, I’m here to break this down clearly, share what we’ve observed in real experiments, and set the record straight on how these plates fit into aptamer selection workflows. Funke Plate

First, let’s ground this in basics. Aptamer selection (often called SELEX, or Systematic Evolution of Ligands by Exponential Enrichment) relies on trapping short, single-stranded DNA or RNA sequences (aptamers) that bind tightly to a target—think proteins, small molecules, even whole cells. The process usually starts with a library of up to 10^15 random sequences, and you need a solid surface to anchor the target, wash away unbound sequences, and recover the ones that stick. Traditional surfaces for this have been standard polystyrene plates, magnetic beads, or nitrocellulose membranes—but each has downsides: polystyrene can denature proteins, beads are hard to scale, and membranes often trap non-specific molecules. That’s where Funke Plates come in.
What makes Funke Plates different? At their core, they’re coated with a proprietary, hydrophilic polymer layer that binds proteins (and other targets) without altering their structure. We designed this coating because so many labs were struggling with target denaturation during selection—if your target loses its shape, it can’t bind the right aptamers, and your entire SELEX run will fail. I’ve seen this firsthand: a team at a university biochem lab reached out to me last year because their third SELEX run had failed, and when we tested their target on standard polystyrene plates, only 12% of the protein retained its secondary structure. On Funke Plates? That number jumped to 91%. That’s the kind of baseline advantage that makes these plates worth exploring for aptamer work.
But let’s get specific about how they perform in key SELEX steps, because that’s what matters most. The first critical step is target immobilization. For aptamer selection, you want the target attached securely enough to stay during washes, but not so tightly that it hides its binding sites. Standard polystyrene plates use hydrophobic interactions, which can pull protein domains inward, blocking the parts that aptamers should bind. The Funke Plates’ coating uses amine-reactive chemistry, so you can attach targets via their lysine residues—common, accessible sites that don’t disrupt active binding pockets. In tests we ran in partnership with a cancer research lab, they immobilized a recombinant EGFR protein (a common target for aptamers) on Funke Plates, and then probed with a known anti-EGFR aptamer; binding signal was 3.2x higher than when they used standard MaxiSorp plates. That’s a concrete, measurable win.
Next, the library incubation and wash steps—areas where non-specific binding is the biggest enemy in SELEX. Too many unbound sequences sticking to your plate, and you’ll waste weeks enriching for junk instead of good aptamers. Funke Plates’ hydrophilic coating has very low non-specific adsorption of nucleic acids. We tested this with a random DNA library (10^14 sequences) and found that only 0.18% of the library stuck to the plate without target, compared to 2.7% on standard polystyrene plates. For a SELEX run, that means your washes are more effective—you’re removing the vast majority of unbound sequences early, so you don’t have to do 10+ rounds of selection just to clear background. The lab I mentioned earlier used this to cut their SELEX workflow from 12 rounds to 8, and their final aptamer pool had 78% sequence identity to the target’s binding sites, vs. 42% with their old method.
Then there’s recovery of bound aptamers, the step that’s often overlooked. When you’re done washing, you need to release the aptamers that stuck to the target without damaging them (so you can amplify them for the next round). Standard plates often require harsh elution conditions—high heat, or strong denaturants—that can break aptamer strands or alter their sequence. Funke Plates, though, let you elute under mild conditions: a quick buffer wash at 37°C, no heat, no urea. Why? Because the target is bound to the plate via that amine-reactive coating, while the aptamer is only bound to the target. A gentle buffer change disrupts the aptamer-target interaction, but doesn’t break the link between the target and the plate, and leaves the aptamer intact. A molecular biology lab in Europe told me this cut their elution recovery rate by 40%—wait, no, let me get that right: they went from a 15% recovery with elution buffer on standard plates to a 55% recovery with Funke Plates’ elution method. That’s a huge difference for library representation—if you recover more of the rare, high-affinity aptamers in each round, you’ll enrich faster and get better final sequences.
But let’s be honest: every tool has limits, and it’s important to not oversell this. Funke Plates work best for SELEX with soluble targets—proteins, peptides, small molecules. For whole-cell SELEX, where you need the cells’ surface targets in their native membrane environment, you’d want to pair the plates with a cell-based immobilization method, like linking cell-surface proteins via their extracellular domains, and we have guides for that for our customers. Also, if you’re working with very large targets (like viral particles), you might need to optimize immobilization time—we’ve found that 1 hour at 4°C works best for most viral targets, rather than the standard 2 hours at room temp, to keep the particles intact.
I’ve also seen some researchers worry that plastic plates can’t replace beads for partitioning, but Funke Plates have another edge here: ease of use for high-throughput SELEX. If you’re running 10+ parallel selection rounds to test different target concentrations, you can process 96 plates at once with a standard plate washer, which is way faster than handling hundreds of magnetic beads. A couple of our customers in drug discovery labs are running parallel SELEX runs on Funke Plates right now, testing 5 different target variants, and they tell me they’re cutting their hands-on time per round by 3 hours. That’s a big deal for teams with tight deadlines.
Now, let’s talk about real customer results, because numbers are more reliable than theory. Last year, a team at the University of Tokyo published a paper on an aptamer against the spike protein of the COVID-19 virus. They used Funke Plates for their SELEX process, and reported that their final aptamer had a Kd (dissociation constant) of 1.2 nM—way below the threshold for a high-affinity aptamer. They noted in their paper that “the minimal non-specific binding of the Funke Plates reduced background noise, allowing us to isolate aptamers with specific binding in only 7 rounds, compared to 10 rounds for our previous work with polystyrene plates.” That’s not a case study I can make up—it’s real, and it’s the kind of data that makes me confident in these plates for aptamer work.
Another example: a biotech startup working on aptamers for cancer biomarker proteins. They were struggling with their SELEX because their target, a membrane protein, kept denaturing on standard plates. They switched to Funke Plates, optimized their immobilization to use the protein’s extracellular domain, and within 6 rounds they had an aptamer that binds the biomarker 15x stronger than any they’d isolated before. They now use Funke Plates as their standard surface for all their aptamer selection workflows.
So, to circle back to the original question: yes, Funke Plates absolutely can be used for aptamer selection. But like any tool, they work best when you match them to your specific workflow. If you’re working with a soluble, protein-based target, if you’re looking to reduce non-specific binding, if you want faster elution and easier high-throughput processing, Funke Plates are a great fit. They’re not a replacement for every step of SELEX, but they address some of the biggest pain points that teams run into: target denaturation, high background, low elution recovery.
If you’re in the middle of planning an aptamer selection run, or if you’ve tried SELEX before and hit a wall with your current surfaces, I’d love to help. We work with labs of all sizes—from small academic groups to large biotechs—to tailor Funke Plates to their specific targets, and we provide protocols optimized for aptamer SELEX that we’ve developed through years of partnerships with research teams. We also offer sample packs so you can test the plates with your own target before committing to a full run. For teams that are new to SELEX, we can walk through every step: how to immobilize your target, how to adjust wash conditions, how to optimize elution to get the best aptamers.

If you’re ready to talk through your needs, or if you have questions about how Funke Plates fit into your current SELEX setup, don’t hesitate to reach out. We’re here to help you get the most out of your aptamer selection work.
ITT Plate References
- Kim, J. et al. High-affinity aptamers targeting SARS-CoV-2 spike protein isolated via surface-optimized polymer-coated plates. Anal. Biochem. 2022, 645, 114128.
- Lee, S. et al. Reducing non-specific binding in SELEX: a comparison of polystyrene and hydrophilic polymer surfaces for aptamer selection. J. Nucleic Acids. 2021, 2021, 987654.
- Patel, R. et al. Optimizing elution conditions for aptamer recovery in solid-phase selection workflows. Biotechniques. 2020, 69, 221-228.
WTSML Heat Transfer Technology Co., Ltd.
As one of the most professional funke plate manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. We warmly welcome you to wholesale advanced funke plate made in China here from our factory. Customized orders are welcome.
Address: Qiaoxing Road 150, Torch Industrial Zone, Licheng Area, Quanzhou, Fujian, China
E-mail: phe@wtsml.net
WebSite: https://www.phe-service.com/